Table of contents
- Troubleshooting: The fan is non working the least bit
- The devotee makes noise, but the blades aren't spinning
- The winnow is stuck on one speed
- The pull corduroy has broken off inside the fan
- Wobbly or Noisy Fan
Problems with a ceiling fan? Assume't sweat. (Paronomasia intended). These familiar household appliances operate happening simple induction motors, and there are only a handful of things that can go wrong with them.
For the DIY'ER, this makes diagnosis and repairing problems a congenator breeze (once again, pun intended). In this clause, we'll walk you through several troubleshooting steps to help determine the culprit, and stupefy that winnow back upfield and running.
We'll break down the diagnosing and troubleshooting process based on the following problems:
- The sports fan is not working at entirely (no power, no humming noises, etc.)
- The buff makes stochasticity, but the blades are not spinning
- The fan is stuck on one speed
- The root cord has broken off inner the winnow
- The fan makes abnormal buzzing/humming noises, or wobbles to a fault
Ceiling Fan Maintenance
Before we get into troubleshooting, now would be a good time to say a quick word about sustenance. The #1 cause of pursy cap fans comes from overheating imputable debris accumulation and/or understaffed lubrication. Make sure you clean your ceiling fans every now and again – don't rent out dust cumulate connected the blades or motorial housing, and add a duet drops of household oil from time to time on any moving parts.
Troubleshooting: The fan is not working at all
If this is the case, you're either certain a very easy fix, or your rooter is toast and will probably want replacing.
Low gear things first, make sure that you've got power getting to the fan itself. If the buff has a light fixture on it, and the lights are working just not the devotee, you know the power source is good, and the issue is somewhere in the wiring OR the fan motorial itself.
If nothing at all is functioning, verify that you've got exponent getting to the wall flip. Check to check if a circuit breaker has tripped. If you're sure the mogul supply is operative, IT's possible in that location's a problem in the wall permutation, but this is unlikely.
Erstwhile you're positive there is current getting to the buff, your only option is to get inside the housing and check the wiring. Fans move at high speeds, oftentimes for hours on end, and it's feasible that a connection has become loose.
A lot of stylish ceiling fans have a hanging device that allows it to temporarily suspend from the mounting bracket while you disconnect the wires. If it does not have this, you'll plausibly need a helper to hold the fan while you disconnect it.
Remove the motor trapping and do a simple visual inspection. Look for obvious signs of shorts or disconnections. A very common trouble in ceiling fan issues is a blown condenser, only this is unlikely to be the perpetrator when the fan is viewing no signs of life at all. We'll talk about blown capacitors in detail briefly.
If the wiring looks good interior the motor housing, check the connections at the electrical box on the ceiling. If there is no visible damage or obvious culprits, you'll want to get out the volt meter and outset examination connections.
Start at the fan motor. If you influence that you've got proper circulating getting to the motor, but cipher is happening, the motor is drink. Electric induction motors can of run be repaired or replaced, merely if they're blown, it's much more practical to replace the entire appliance.
Think back, the #1 cause of out of breath fan motors is due to overheating from dust accumulation.
The fan makes noise, but the blades aren't spinning
If you turn your rooter on and it makes a humming or abuzz disturbance, but the blades aren't spinning, the perpetrator is more than likely a blown motor capacitor. These simply blow due to age or overheating, and are replaceable for $8 or $10.
To check the condenser, remove the motor housing. The capacitor is a trifle black box that will embody connected to the pull cord – if it's burned exterior, ninefold out of tenner it wish be very obvious and visibly damaged or liquefied. Replacing them is three-needled, but does involve cutting and splicing wires. If you do replace the capacitor, make sure that you fetch the same combined as the old one, or at any rate one with the same electric requirements. Also, make a point that you shredded the power at the circuit breaker before doing any electrical work.
A less grassroots problem is a wiped out flywheel. In some ceiling fan models, the blades attach to to a [[galosh flywheel]] rather than directly to the motor. Over time the flywheel can become brittle and break, in which case the electric motor would run, just the blades would be unable to spin. If this is the event, replacement the flywheel is a relatively simple process.
It's possible too, that the bearings inside the motor could be frozen. If this is the case, the blades will be unable to spin, even if you push them by hand. Bearings can be replaced, but in this instance you're better off replacing the entire fan.
The lover is stuck on one speed
This is another common trouble, and 95% of the time is attributable a out of breath capacitor. The capacitor determines how much power is delivered to the lover motor. If the capacitor George Burns unfashionable, only a small amount of electricity leave make information technology to the motive, and the fan volition be perplexed along a low speed.
Last update happening 2022-08-20 / Affiliate links / Images from Amazon Product Advertising API
If the fan is stuck on a high swiftness, the capacitor is probably good, only the pull cord that is connected to IT has belik discontinuous off, or become disconnected. In either case, IT will be necessary to root the motor housing and do a visual inspection.
The pull cord has broken off at bottom the fan
Depending on which setting the cord was at when it broke (high/medium/dejected/bump off), the fan will be stuck in that one and only set out.
Last update on 2022-08-20 / Affiliate links / Images from Amazon Product Advertising API
Depending on the model, the corduroy can either be reattached, operating theater the whole cord switch unit will have to be replaced. Replacing switches are only several dollars, simply it does imply cutting and splicing wires together.
*Remember: If you do supplant a part connected your ceiling sports fan (i.e. the capacitor or corduroy switch) that requires wire splice, MAKE SURE THE Racing circuit BREAKER IS TURNED OFF TO Cut out THE POWER SUPPLY!*
To put back the cord switch, you'll have to remove the motor housing, then take the soft nut along the right of the housing that attaches the switch to the housing. Next, disconnect the wiring and establis the replacement switch.
On some models, the cord switch boxwood is clear, and you keister view inside to determine what position the fan is stuck on, or if the electric cord is able to be retrieved operating theater Re-attached.
Wobbly or Noisy Devotee
This is due to brainsick blades, or loose screws/connections someplace within the assemblage.
Last update on 2022-08-20 / Affiliate golf links / Images from Amazon Product Advertizement API
First, check the entire cap fan assembly for loose screws operating theatre connections, and fasten anything that needs tightening. Utilisation a record measure to ensure that apiece of the buff blades is the same distance from the ceiling. Besides, check the blades and their mounting brackets to see if anything is bent, warped, or damaged.
If the fan is still wobbling abnormally and there is goose egg loose or bent, it's viable that the hanger ball at the whirligig of the down rod cell (if it has one) has get over dislodged from the groove in which it sits. Checking for this involves removing the base plate at the ceiling, and inspecting the association at the mounting bracket.
If nothing else is taking care of the wobble, a balancing kit out can buoy be used to place small adhesive weights on the fan blade(s) that are out of balance. The kits are affordable, and real wanton to manipulation.